![Sony DVW-250 Скачать руководство пользователя страница 216](http://html.mh-extra.com/html/sony/dvw-250/dvw-250_maintenance-manual_410988216.webp)
7-42
DVW-250/250P
7-2-18. Self REC/PB Tracking Check
Tools
• Blank tape BCT-D124L
• Oscilloscope
• Regulated DC power supply (AC-550/550CE or equiva-
lent)
Settings
1.
Turn the power off.
2.
Remove the top panel.
(Refer to “1-5. Removal/Installation of Cabinet”.)
3.
Open the ornamental plate on the left side panel.
(Refer to “1-13. Tracking Adjustment”.)
4.
Connect an oscilloscope
CH-1: TP1/MB-601 (AE)
TRIG: TP8/MB-601 (CF)
5.
Connect a regulated DC power supply to DC IN
connector on the connector panel.
6.
Turn the power on.
7.
On the setup menu, set AUTO TRACKING to OFF.
checks
1. Recording the test signal (1)
(1) To display the DIAG menu on the display, press the
DIAG button using a tip of a clip or equivalent.
(2) Move the cursor (“
*
”) to “TEST” on the menu, and
press the SET button.
(3) Move the cursor to “TTP”, and press the SET button.
(4) Move the cursor to “PATH”, and press the SET
button.
(5) Move the cursor to “TEST SG”, and press the SET
button.
(6) To display the “A2” to the right side of “TEST SG”,
press the UP/DOWN button several times. Then, 8
MHz test signal for video A,C,E and G channels is
generated.
(7) Insert a blank tape and press the REC and PLAY
button simultaneously so that the test signal is record-
ed.
(8) Record the signal about 10 minutes and rewind the
tape.
(9) Play back the recorded portion of the test signal.
7-2-18. Self REC/PB Tracking Check