![SMC Networks LECSB Series Скачать руководство пользователя страница 421](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641421.webp)
App. - 12
APPENDIX
(10) Overload protection characteristics
An electronic thermal relay is built in the driver to protect the servo motor, driver and servo motor power line
from overloads. The operation characteristics of the electronic thermal relay are shown below. It is
recommended to use an unbalanced torque-generated machine, such as a vertical motion shaft, so that
unbalanced torque is not more than 70
of the rated torque. When you carry out adhesion mounting of the
driver, make circumference temperature into 0 to 45
(32 to 113 ) or use it with 75
or less of effective
load torque.
Driver LECSB
□
-
□
series have servo motor overload protection. (The motor full load current is 115
rated
current.)
1000
100
10
1
0.1
100
200
300
350
0
(Note 2) Load ratio [ ]
In servo lock
In operation
O
pe
ra
tio
n t
im
e [
s
]
1000
100
10
1
0.1
100
200
300
350
0
In servo lock
In operation
O
pe
ra
tio
n t
im
e [
s
]
(Note 2) Load ratio [ ]
LECSB
□
-S5
LECSB
□
-S7
LECSB2-S8