![SMC Networks LECSB Series Скачать руководство пользователя страница 142](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641142.webp)
5 - 23
5. PARAMETERS
No.
Symbol
Name and function
Initial
value
Unit
Setting
range
Control mode
Position Speed Torque
PB05
For manufacturer setting
Do not change this value by any means.
500
PB06
GD2
Ratio of load inertia moment to servo motor inertia moment
Used to set the ratio of the load inertia moment to the servo
motor shaft inertia moment. When auto tuning mode 1 and
interpolation mode is selected, the result of auto tuning is
automatically used.
(Refer to section 7.1.1)
In this case, it varies between 0 and 100.0.
7.0
Multi-
plier
(
1)
0
to
300.0
PB07
PG1
Model loop gain
Set the response gain up to the target position.
Increase the gain to improve track ability in response to the
command.
When auto turning mode 1
2 is selected, the result of auto
turning is automatically used.
24
rad/s
1
to
2000
PB08
PG2
Position loop gain
Used to set the gain of the position loop.
Set this parameter to increase the position response to level
load disturbance. Higher setting increases the response
level but is liable to generate vibration and/or noise.
When auto tuning mode 1
2 and interpolation mode is
selected, the result of auto tuning is automatically used.
37
rad/s
1
to
1000
PB09
VG2
Speed loop gain
Used to set the gain of the speed loop.
Set this parameter when vibration occurs on machines of
low rigidity or large backlash.
Higher setting increases the response level but is liable to
generate vibration and/or noise.
When auto tuning mode 1
2, manual mode and
interpolation mode is selected, the result of auto tuning is
automatically used.
823
rad/s
20
to
50000
(Note)
PB10
VIC
Speed integral compensation
Used to set the integral time constant of the speed loop.
Lower setting increases the response level but is liable to
generate vibration and/or noise.
When auto tuning mode 1
2 and interpolation mode is
selected, the result of auto tuning is automatically used.
33.7
ms
0.1
to
1000.0
PB11
VDC
Speed differential compensation
Used to set the differential compensation.
Made valid when the proportion control (PC) is switched on.
980
0
to
1000
Содержание LECSB Series