5 - 7
5. PARAMETERS
5.1.7 Number of command input pulses per servo motor revolution
Parameter
Initial
value
Unit
Setting
range
Control mode
No.
Symbol
Name
Position Speed Torque
PA05
*FBP
Number of command input pulses per revolution
0
0
1000
to 50000
POINT
Turn off the power and then on again after setting the parameter to validate the
parameter value.
When "0" (initial value) is set in parameter No.PA05, the electronic gear (parameter No.PA06, PA07) is made
valid. When the setting is other than "0", that value is used as the command input pulses necessary to rotate
the servo motor one turn. At this time, the electronic gear is made invalid.
CDV
FBP
Command
pulse train
Pt
Other than "0"
"0"(Initial value)
CMX
Servo motor
Encoder
M
Number of command input pulses
per revolution
Parameter No.PA05
Electronic gear
Parameter No.PA06, PA07
Deviation
counter
Pt (Encoder resolution of servo motor): 262144 [pule/rev]
Parameter No.PA05 setting
Description
0
Electronic gear (parameter No.PA06, PA07) is made valid.
1000 to 50000
Number of command input pulses necessary to rotate the servo motor one turn [pulse]
Содержание LECSB Series
Страница 1: ...PRODUCT NAME AC Servo Motor Driver MODEL Series LECSB Series Doc no JXC OMT0021 B ...
Страница 17: ...7 App 6 Compliance with the European EC directives App 7 App 7 Conformance with UL C UL standard App 10 ...
Страница 255: ...10 1 10 OUTLINE DRAWINGS 10 OUTLINE DRAWINGS 2 10 1 Driver 2 10 2 Connector 4 ...