![SMC Networks LECSB Series Скачать руководство пользователя страница 130](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641130.webp)
5 - 11
5. PARAMETERS
To rotate the servo motor at 3000r/min in the open collector system (200kpulse/s), set the electronic gear
as follows.
CDV
CMX
N
0
f
60
Pt
f
: Input pulses frequency [pulse/s]
N
0
: Servo motor speed [r/min]
Pt : Encoder resolution of servo motor [pulse/rev]
200
60
CDV
CMX
3000
262144
CDV
CMX
3000
60
262144
200
60 200000
3000 262144
8192
125
10
3
10
3
The following table indicates the electronic gear setting example (ball screw lead 10mm) when the QD75
is used in this way.
Rated servo motor speed
3000r/min
2000r/min
Driver
Input system
Open
collector
Differential
line driver
Open
collector
Differential
line driver
Max. input pulse frequency [pulse/s]
200k
1M
200k
1M
Feedback pulse/revolution [pulse/rev]
262144
262144
Electronic gear (CMX/CDV)
8192/125
8192/625
16384/375
16384/1875
QD75
Command pulse frequency [kpulse/s] (Note)
200k
1M
200k
1M
Number of pulses per servo motor revolution as
viewed from QD75[pulse/rev]
4000
20000
6000
30000
Electronic gear
Minimum command unit
1pulse
AP
1
1
1
1
AL
1
1
1
1
AM
1
1
1
1
Minimum command unit
0.1 m
AP
4000
20000
6000
30000
AL
100.0[ m]
100.0[ m]
100.0[ m]
100.0[ m]
AM
10
10
10
10
Note. Command pulse frequency at rated speed
POINT
In addition to the setting method using the electronic gear given here, the
number of pulses per servo motor revolution can also be set directly using
parameter No.PA05. In this case, parameter No.PA05 is the "Number of pulses
per servo motor revolution as viewed from QD75".