6.9.4 Motor-less operation
Without connecting the servo motor, you can provide output signals or monitor the status display as if the servo
motor is running in response to input device. This operation can be used to check the sequence of a PC or
PLC…etc or the like.
(1) Operation
Turn SON off, and then select motor-less operation. After that, perform external operation as in ordinary
operation.
(2) Status display
Change the display to the status display screen by pressing the "MODE" button. (Refer to section 6.2.)
The status screen can be changed by pressing the "UP" or the "DOWN" button. (Refer to section 6.3.)
(3) Termination of motor-less operation
To terminate the motor-less operation, switch power off.