![SMC Networks LECSB Series Скачать руководство пользователя страница 377](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641377.webp)
14 - 40
14. ABSOLUTE POSITION DETECTION SYSTEM
(b) Device list
X input contact
Y output contact
X20
ABS Transmission data bit 0 / positioning
Y30
Servo-on
completion
Y31
ABS transfer mode
X21
ABS Transmission data bit 1 / zero speed
Y32
ABS request
detection
Y33
Alarm reset
X22
Reading to send ABS data / limiting torque
Y34
(Note 2)
Electromagnetic brake output
X23
Servo alarm
Y35
(Note 1)
Clear
X24
Alarm reset switch
Y38
Servo alarm
X25
Servo emergency stop
Y39
ABS communication error
X26
Servo-on switch
Y3A
ABS checksum error
X27
Home position return start switch
M contact
X28
Operation mode I
M5
ABS data transmission start
X29
Operation mode II
M6
Sum check completion
D register
M7
Sum check mismatch
D0
ABS data transmission counter
M8
ABS data ready
D1
Checksum transmission counter
M9
Transmission data read enabled
D2
Checksum addition register
M10
Checksum 2 bits read completion
D3
ABS data: Lower 16 bits
M11
ABS 2 bits read completion
D4
ABS data: Upper 16 bits
M12
ABS 2 bits request
D5
ABS data 2-bit receiving buffer
M13
Servo-on request
D6
Check data in case of checksum error
M14
Servo alarm
D7
Number of retries
M15
ABS data transfer retry start flag set
D8
Forward rotation direction
M16
Retry flag set
D9
Home position address: Lower 16 bits
M17
Retry flag reset
D10
Home position address: Upper 16 bits
M18
PLS processing command
D11
Drive unit ready data
M20
(Note 1)
Clear (CR) ON timer request
D12
Home position return completion data
M21
(Note 1)
Data set type home position return request
D110
Received shift data: Lower 16 bits
M22
Home position return processing instruction
D111
Received shift data: Upper 16 bits
M23
Current position change processing
T timer
instruction
T0
ABS transmission mode timer
M24
Current position change flag
T1
ABS request response timer
M26
ABS transfer mode OFF permission
T2
Retry wait timer
C counter
T3
ABS data send reading response timer
C0
ABS data receive times counter
T10
(Note 1)
Clear (CR) ON timer
C1
Checksum receive times counter
T200
Transmitted data read 10ms delay timer
C2
Retry counter
T211
Retry ABS transfer mode OFF wait timer
20ms set
Note 1. Required for data set type home position return.
2. Required for electromagnetic brake output.