![SMC Networks LECSB Series Скачать руководство пользователя страница 143](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641143.webp)
5 - 24
5. PARAMETERS
No.
Symbol
Name and function
Initial
value
Unit
Setting
range
Control mode
Position Speed Torque
PB12
OVA
(Note)
Overshoot amount compensation
Used to suppress overshoot in position control.
Overshoot can be suppressed in machines with high friction.
Set a control ratio against the friction torque in percentage
unit.
Overshoot amount compensation can be set as shown in
the following table in parameter No.PA01 (control mode).
0
0
to
100
Parameter
No.PA01
Overshoot amount compensation
0
Set value of parameter No.PB12
3
4
Automatically set (5
) when "0"
is set in parameter No.PB12
Set value of parameter No.PB12
when a value other than "0" is set
in parameter No.PB12
5
PB13
NH1
Machine resonance suppression filter 1
Set the notch frequency of the machine resonance
suppression filter 1.
Setting parameter No.PB01 (Adaptive tuning mode
(Adaptive filter )) to "
1" automatically changes this
parameter.
When the parameter No.PB01 setting is "
0", the
setting of this parameter is ignored.
4500
Hz
100
to
4500