14. ABSOLUTE POSITION DETECTION SYSTEM
(f) Data set type home position return
After jogging the machine to the position where the home position (e.g. 500) is to be set, choose the
home position return mode and set the home position with the home position return start switch (X27)
ON.
After switching power on, rotate the servo motor more than 1 revolution before starting home position
return.
Do not turn ON the clear (CR) (Y35) for an operation other than home position return. Turning it on in
other circumstances will cause position shift.
M9039
Y1D
Y31
X20
X27
M20
M21
T10
M20
PLS
M21
D9
K500
DMOVP
K1
D9
K72
H0000
DTOP
K1
D9
K1154
H0000
DTOP
T10
M21
SET
K1
M21
RST
Y35
(Note 1)
K1
K9003
K1150
H0000
TO
Y10
SET
X1
X4
Y10
Y10
RST
XA
Programmable controller ready
Clear (CR) ON timer request
Clear (CR) 100ms ON timer
Setting data set type home position return request
Resetting data set type home position return
request
Switch clear (CR) on
Setting X-axis home position address 500
in data register
*1: Changing X-axis home position address
(Note 2)
*1: Changing X-axis current value
*1: Writing positioning data No.9003
Starting positioning
Switching BUSY signal off to switch start
signal off.
PC RUN
Home position
return mode
ABS transfer
mode
Positioning
completion
Home position
return start switch
Clear signal ON
timer request
Data set type home position return request
Clear signal 100ms ON timer
Data set type home position
return request
Positioning
start
Start
completion
BUSY
Error detection
Note 1. When the data of the home position address parameter is not written from GX Developer or the like before starting the data set
type home position return program, this sequence circuit is required.
When the home position address is written in the home position address parameter, change to the following circuit.
K1
D9
K72
H0000
DFROP
(Note 2)
2. Changes are stored temporarily to buffer memory at this time. An additional processing is required when changes should be
reflected to memory for OS or flash ROM. For details, refer to the positioning module user's manual.
Содержание LECSB Series
Страница 1: ...PRODUCT NAME AC Servo Motor Driver MODEL Series LECSB Series Doc no JXC OMT0021 B ...
Страница 17: ...7 App 6 Compliance with the European EC directives App 7 App 7 Conformance with UL C UL standard App 10 ...
Страница 255: ...10 1 10 OUTLINE DRAWINGS 10 OUTLINE DRAWINGS 2 10 1 Driver 2 10 2 Connector 4 ...