![SMC Networks LECSB Series Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641145.webp)
5 - 26
5. PARAMETERS
No.
Symbol
Name and function
Initial
value
Unit
Setting
range
Control mode
Position Speed Torque
PB15
NH2
Machine resonance suppression filter 2
Set the notch frequency of the machine resonance
suppression filter 2.
Set parameter No.PB16 (notch shape selection 2) to
"
1" to make this parameter valid.
4500
Hz
100
to
4500
PB16
NHQ2 Notch shape selection 2
Select the shape of the machine resonance suppression
filter 2.
14dB
8dB
4dB
0
Notch depth selection
Setting value
Depth
Gain
Deep
Shallow
40dB
to
0
1
2
3
3
4
5
Notch width selection
Setting value
Width
Standard
Wide
2
to
0
1
2
3
Machine resonance suppression filter 2 selection
0: Invalid
1: Valid
0000h
Refer to
name
and
function
column.
PB17
Automatic setting parameter
The value of this parameter is set according to a set value of
parameter No.PB06 (Ratio of load inertia moment to servo
motor inertia moment).
PB18
LPF
Low-pass filter setting
Set the low-pass filter.
Setting parameter No.PB23 (low-pass filter selection) to
"
0
" automatically changes this parameter.
When parameter No.PB23 is set to "
1
", this
parameter can be set manually.
3141
rad/s
100
to
18000
PB19
VRF1
Vibration suppression control vibration frequency setting
Set the vibration frequency for vibration suppression control
to suppress low-frequency machine vibration, such as
enclosure vibration.
Setting parameter No.PB02 (vibration suppression control
tuning mode) to "
1" automatically changes this
parameter. When parameter No.PB02 is set to "
2",
this parameter can be set manually.
100.0
Hz
0.1
to
100.0
PB20
VRF2
Vibration suppression control resonance frequency setting
Set the resonance frequency for vibration suppression
control to suppress low-frequency machine vibration, such
as enclosure vibration.
Setting parameter No.PB02 (vibration suppression control
tuning mode) to "
1" automatically changes this
parameter. When parameter No.PB02 is set to "
2",
this parameter can be set manually.
100.0
Hz
0.1
to
100.0
PB21
For manufacturer setting
0.00
PB22
Do not change this value by any means.
0.00
Содержание LECSB Series
Страница 1: ...PRODUCT NAME AC Servo Motor Driver MODEL Series LECSB Series Doc no JXC OMT0021 B ...
Страница 17: ...7 App 6 Compliance with the European EC directives App 7 App 7 Conformance with UL C UL standard App 10 ...
Страница 255: ...10 1 10 OUTLINE DRAWINGS 10 OUTLINE DRAWINGS 2 10 1 Driver 2 10 2 Connector 4 ...