3 - 64
3. SIGNALS AND WIRING
3.12 Grounding
WARNING
Ground the driver and servo motor securely.
To prevent an electric shock, always connect the protective earth (PE) terminal
(terminal marked
) of the driver with the protective earth (PE) of the control box.
The driver switches the power transistor on-off to supply power to the servo motor. Depending on the wiring
and ground cable routing, the driver may be affected by the switching noise (due to di/dt and dv/dt) of the
transistor. To prevent such a fault, refer to the following diagram and always ground.
To conform to the EMC Directive, refer to the EMC Installation Guidelines (IB(NA)67310).
(Note)
Power supply
W
V
U
Ensure to connect it to PE
terminal of the servo amplifier.
Do not connect it directly to the
protective earth of the control
panel.
Control box
Servo motor
M
U
V
W
Encoder
CN2
Servo amplifier
L
11
L
1
L
2
L
3
L
21
CN1
Protective earth (PE)
Outer
box
MC
NFB
L
ine
f
ilt
er
P
ro
g
ra
m
m
ab
le
c
on
tr
o
lle
r
Note. For 1-phase 200 to 230VAC or 1-phase 100 to 120VAC, connect the power supply to L
1
L
2
and leave L
3
open.
There is no L
3
for 1-phase 100 to 120VAC power supply. For the specification of power supply, refer to section 1.3.
Driver
driver.
PC or
PLC…etc
Содержание LECSB Series
Страница 1: ...PRODUCT NAME AC Servo Motor Driver MODEL Series LECSB Series Doc no JXC OMT0021 B ...
Страница 17: ...7 App 6 Compliance with the European EC directives App 7 App 7 Conformance with UL C UL standard App 10 ...
Страница 255: ...10 1 10 OUTLINE DRAWINGS 10 OUTLINE DRAWINGS 2 10 1 Driver 2 10 2 Connector 4 ...