14 - 52
14. ABSOLUTE POSITION DETECTION SYSTEM
Note 1. For the dog type home position return. Need not be connected for the data set type home position return.
2. For the dog type home position return, connect a QD75 deviation counter clearing signal cable. For the data set type home
position return, connect a cable to the output module of the programmable PC or PLC...etc.
3. This circuit is provided for your reference.
4. The electromagnetic brake output should be controlled via a relay connected to the programmable PC or PLC...etc output.
5. Refer to section 3.8.2 (3)(b) and Type QD75P/QD75D Positioning Module User’s Manual when connecting to QD75P.
(2) Sequence program example
(a) Conditions
The ABS data is transmitted using the leading edge of the servo-on switch as a trigger.
1) When the servo-on switch and power supply GND are shorted, the ABS data is transmitted at power-
on of the driver or on the leading edge of the RUN signal after a PC reset operation (PC-RESET).
The ABS data is also transmitted when an alarm is reset or when an emergency stop is reset.
2) An ABS checksum error is caused (Y3AON) if checksum inconsistency is found in transferred data.
3) The following time periods are measured. If the ON/OFF state does not change within the specified
time, the ABS communication error occurs change within the specified time, the ABS communication
error occurs (Y3A ON).
ON period of ABS transfer mode (Y31)
ON period of ABS request (Y32)
OFF period of reading to send ABS data (X22)
(b) Device list
X input contact
Y output contact
X20
ABS transmission data bit 0/Positioning completion Y30
Servo-on
X21
ABS transmission data bit 1/zero speed detection
Y31
ABS transfer mode
X22
ABS transmission data ready/Torque limiting
Y32
ABS request
X23
Servo alarm
Y33
Alarm reset
X24
Alarm reset switch
Y34
(Note 2)
Electromagnetic brake output
X25
Servo emergency stop
Y35
(Note 1)
Clear
X26
Servo-on switch
Y38
Servo alarm
X27
Home position return start switch
Y39
ABS communication error
X28
Operation mode I
Y3A
ABS checksum error
X29
Operation mode II
D register
M contact
D0
Number of retries
M0
End of error reset
D9
Home position address: Lower 16 bits
M10
Preparation completion
D10
Home position address: Upper 16 bits
M11
Servo-on request
D100 to D104 For absolute position restoration dedicated
M12
Absolute position restoration instruction PLS
instruction
M13
Absolute position restoration memory
T timer
M14
Error flag output
T0
Retry wait timer
M15
Sum check NG
T10
(Note 1)
Clear (CR) ON timer
M16
Retry flag
M17
Retry flag reset request
M20
(Note 1)
Clear (CR) ON timer request
M21
(Note 1)
Data set type home position return request
M100 to M101 For absolute position restoration dedicated
instruction
C counter
C0
Retry counter
Note 1. Required for data set type home position return.
2. Required for electromagnetic brake output.