5. PARAMETERS
No.
Symbol
Name and function
Initial
value
Unit
Setting
range
Control mode
Position Speed Torque
PC22 *COP1 Function selection C-1
Select the execution of automatic restart after instantaneous
power failure selection, and encoder cable communication
system selection.
0 0
Restart after instantaneous power failure
selection
If the power supply voltage has returned to
normal after an undervoltage status caused by
the reduction of the input power supply voltage
in the speed control mode, the servo motor can
be restarted by merely turning on the start
signal without resetting the alarm.
0: Invalid (Undervoltage alarm (AL.10) occurs.)
1: Valid (If this function is enabled for the drive
unit of 30kW or more, the parameter error
(AL.37) occurs.)
Encoder cable communication system
selection
0: Two-wire type
1: Four-wire type
Incorrect setting will result in an encoder error
1 (At power ON) (AL.16).
Refer to section 12.1.2 for the communication
method of the encoder cable.
0000h
Refer to
name
and
function
column.
The following cables are of 2-wire type.
LE-CSE-
□2□ / LE-CSE-□5□ / LE-CSE-□A□
Incorrect settinf will result in an encoder alarm1(A16)