![SMC Networks LECSB Series Скачать руководство пользователя страница 366](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641366.webp)
14 - 29
14. ABSOLUTE POSITION DETECTION SYSTEM
(b) Device list
X input contact
Y output contact
X0
Transmission data bit 0 / completion of
positioning
Y0
Y1
Servo-on
ABS transfer mode
X1
Transmission data bit 1 / zero speed detection
Y2
ABS request
X2
Send ABS transmission data ready/ torque limit
control
Y3
Y4
(Note 2)
Alarm reset
Electromagnetic brake output
X3
Servo alarm
Y5
(Note 1)
Clear
X4
Alarm reset switch
Y10
Servo alarm
X5
Servo emergency stop
Y11
ABS communication error
X6
Servo-on switch
Y12
ABS checksum error
X7
Servo ready
X10
JOG ( ) switch
X11
JOG ( ) switch
X12
Position start switch
X13
Position stop switch
X14
Home position return start switch
X15
1PG error reset
D register
M contact
D0
ABS data: Lower 16 bits
M0
Error flag
D1
ABS data: Upper 16 bits
M1
ABS data transmission start
D2
Checksum addition counter
M2
Retry command
D3
Check data in case of checksum error
M3
ABS data read
D4
Transmission retry count in checksum
discrepancy
M4
M5
Servo-on request reset permission
Servo-on request
D24
Home position address: Lower 16 bits
M6
Retry flag
D25
Home position address: Upper 16 bits
M10
M11
M12
M13
ABS data 2 bit receiving buffer
D106
D107
1PG present position address: Lower 16 bits
1PG present position address: Upper 16 bits
M20
M51
ABS data 32 bit buffer
M52
M57
Checksum 6 bit buffer
M58
M59
For checksum comparison
T timer
M62
Sum check discrepancy (greater)
T200
Retry wait timer
M63
Sum check discrepancy
T201
ABS transfer mode timer
M64
Sum check discrepancy (less)
T202
T203
T204
T210
(Note 1)
ABS request response timer
Ready to send response timer
ABS data waiting timer
Clear (CR) ON timer
M70
(Note 1)
M71
(Note 1)
M99
Clear (CR) ON timer request
Data set type home position return request
ABS data ready
T211
Retry ABS transfer mode OFF wait timer 20ms
C counter
set
C0
All data reception frequency counter (19 times)
C1
Checksum reception frequency counter
C2
ABS data reception frequency counter (16 times)
Note 1. Necessary when data set type home position return is executed.
2. Necessary in the event of electromagnetic brake output.