![SMC Networks LECSB Series Скачать руководство пользователя страница 159](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641159.webp)
5 - 40
5. PARAMETERS
No.
Symbol
Name and function
Initial
value
Unit
Setting
range
Control mode
Position Speed Torque
PC26 *COP5 Function selection C-5
Select the stroke limit warning (AL. 99).
Stroke limit warning (AL. 99) selection
0: Valid
1: Invalid
When this parameter is set to "1", AL. 99 will
not occur if the forward rotation stroke end
(LSP) or reverse rotation stroke end (LSN)
turns OFF.
0 0 0
0000h
Refer to
name
and
function
column.
PC27 *COP6 Function selection C-6
Set this function if undervoltage alarm occurs because of
distorted power supply voltage waveform when using power
regenerative converter or power regenerative common
converter.
Setting when undervoltage alarm occurs
0: Initial value (Waveform of power supply voltage is not distorted)
1: Set "1" if undervoltage alarm occurs because of distorted power
supply voltage waveform when using power regenerative
converter or power regenerative common converter.
0 0 0
0000h
Refer to
name
and
function
column.
PC28
For manufacturer setting
0000h
PC29
Do not change this value by any means.
0000h
PC30
STA2
Acceleration time constant 2
This parameter is made valid when the
acceleration/deceleration selection (STAB2) is turned ON.
Used to set the acceleration time required to reach the rated
speed from Or/min in response to the analog speed
command and internal speed commands 1 to 7.
0
ms
0
to
50000
PC31
STB2
Deceleration time constant 2
This parameter is made valid when the
acceleration/deceleration selection (STAB2) is turned ON.
Used to set the deceleration time required to reach Or/min
from the rated speed in response to the analog speed
command and internal speed commands 1 to 7.
0
ms
0
to
50000
PC32
CMX2 Command pulse multiplying factor numerator 2
Available when the parameter No.PA05 is set to "0".
1
1
to
65535
PC33
CMX3 Command pulse multiplying factor numerator 3
Available when the parameter No.PA05 is set to "0".
1
1
to
65535
PC34
CMX4 Command pulse multiplying factor numerator 4
Available when the parameter No.PA05 is set to "0".
1
1
to
65535