6 - 10
6. DISPLAY AND OPERATION SECTIONS
6.5 Alarm mode
The current alarm, past alarm history and parameter error are displayed. The lower 2 digits on the display
indicate the alarm number that has occurred or the parameter number in error. Display examples are shown
below.
Name
Display
Description
Current alarm
Indicates no occurrence of an alarm.
Indicates the occurrence of overvoltage (AL.33).
Flickers at occurrence of the alarm.
Alarm history
Indicates that the last alarm is overload 1 (AL.50).
Indicates that the second alarm in the past is overvoltage (AL.33).
Indicates that the third alarm in the past is undervoltage (AL.10).
Indicates that the fourth alarm in the past is overspeed (AL.31).
Indicates that there is no fifth alarm in the past.
Indicates that there is no sixth alarm in the past.
Name
Display
Description
Parameter error No.
Indicates no occurrence of parameter error (AL.37).
Indicates that the data of parameter No.PA12 is faulty.
Functions at occurrence of an alarm
(1) Any mode screen displays the current alarm.
(2) Even during alarm occurrence, the other screen can be viewed by pressing the button in the operation area.
At this time, the decimal point in the fourth digit remains flickering.