Remote Control Commands
R&S
®
SGT100A
439
User Manual 1176.8674.02 ─ 07
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:BINPut
<BipolarInput>
Enables the generation of a bipolar signal.
Parameters:
<BipolarInput>
0 | 1 | OFF | ON
*RST:
0
Example:
See
Example "Generating an RF envelope signal and defining
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:GAIN
<Gain>
Sets the gain of the used external DC modulator.
Parameters:
<Gain>
float
Range:
-50 to 50
Increment: 0.01
*RST:
0
Example:
See
Example "Generating an RF envelope signal and defining
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:VCC:OFFSet
<VccOffset>
Applies a voltage offset on the supply voltage V
cc
.
Parameters:
<VccOffset>
float
Range:
0 to 10
Increment: 1E-3
*RST:
0
Default unit: mV
Example:
See
Example "Generating an RF envelope signal and defining
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:VCC:MIN
<VccMin>
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:VCC:MAX
<VccMax>
Sets the maximum value of the supply voltage V
cc
.
SOURce Subsystem