Remote Control Commands
R&S
®
SGT100A
312
User Manual 1176.8674.02 ─ 07
Example:
CAL:BBIN:MEAS?
starts the adjustment of the analog I/Q input.
Response: 0
adjustment has been performed successfully.
Usage:
Query only
:CALibration:ALL[:MEASure]?
Starts all internal adjustments for which no external measuring equipment is required.
Return values:
<All>
0 | 1 | OFF | ON
Usage:
Query only
Manual operation:
See
:CALibration:FREQuency[:MEASure]?
Performs all adjustments which affect the frequency.
Return values:
<Synthesis>
0 | 1 | OFF | ON
Usage:
Query only
Manual operation:
See
:CALibration:IQModulator:FULL?
Starts the adjustment of the I/Q modulator for the entire frequency range. The I/Q mod-
ulator is adjusted with respect to carrier leakage, I/Q imbalance and quadrature.
Return values:
<Modulator>
0 | 1 | OFF | ON
Usage:
Query only
Manual operation:
See
:CALibration:IQModulator:LOCal?
Starts the adjustment of the I/Q modulator for the current frequency. The I/Q modulator
is adjusted with respect to carrier leakage, I/Q imbalance and quadrature.
This adjustment is only possible when
:OUTPut[:STATe] ON
and
[:SOURce]:IQ:STATe ON
.
Return values:
<CFRequency>
0 | 1
Usage:
Query only
Manual operation:
See
"Adjust I/Q Modulator at Current Frequency"
CALibration Subsystem