Chapter 8 Troubleshooting
Robotics Diagnostics
Scalar i500 User’s Guide
357
writes two wraps worth of data on each of the two outside data bands on
both edges of the tape for the entire length of the tape. For this test, insert
the suspect cartridge in the top I/E station slot. The data will be
overwritten on the suspect cartridge.
Media tests cannot be performed from the operator panel. The path to
open the appropriate screen is as follows:
• From the web client, select
Tools > Diagnostics > Drives > Media Tests
.
Robotics Diagnostics
The Robotics diagnostics currently include only one test, the Get/Put
Test.
Get/Put Test
8
The Get/Put Test requires the robot to remove one tape cartridge from
the top I/E station slot, and then put the tape cartridge back into the same
slot. To run this test, you must insert a tape into the library’s top
(uppermost) I/E station slot.
Robotics tests cannot be performed from the operator panel. The path to
open the appropriate screen is as follows:
• From the web client, select
Tools > Diagnostics > Robotics > Robotics
Get/Put Test
.