Chapter 7 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration
Scalar i500 User’s Guide
205
c
After raising the robot assembly to the approximate middle of the
control module, hold it in place with one hand and, using your
other hand, move the parking tab in a counter-clockwise
direction until it stops in the “parked” position. The metal
parking tab is located at the bottom of column 1.
d
Gently lower the robot assembly to rest on the parking tab.
Caution:
Support the robot assembly by holding onto the broad
metal X-axis plate. Lifting the robot by the thin metal
rod will bend the rod.