Chapter 7 Installing, Removing, and Replacing
Replacing an Expansion Module
Scalar i500 User’s Guide
261
Preparing to Remove the
Expansion Module
7
Required tools:
• Phillips #2 screwdriver, for removing and replacing the top cover
plate
• T10 TORX screwdriver, for removing and replacing the bottom cover
plate
1
Power off the library.
2
Disconnect all power cords, network data cables, and module-to-
module cables from each module you will be removing.
3
Remove all power supplies from each module that you intend to
remove. For details, see
Adding, Removing, and Replacing Power
Supplies
on page 281.
4
Remove all tape drives from each module that you intend to remove.
For details, see
Adding, Removing, and Replacing Tape Drives
on
page 303.
5
If your library contains FC I/O blades, remove both the I/O blades
and the accompanying fan blades from the expansion module. For
details, see
Adding, Removing, and Replacing FC I/O Blades
on
page 306 and
Adding, Removing, and Replacing the I/O Fan Blade
on page 317.
6
Remove the tape cartridges from each module that you intend to
remove.
Warning:
Without tape drives, tape cartridges, or power
supplies, a control module weighs approximately 58
lbs. An expansion module, without tape drives, tape
cartridges, or power supplies, exceeds 65 lbs.
To avoid serious injury, at least two people are
required to safely lift the modules into position.
Note:
You should label all cables before you remove them so you