MGC Administrator’s Guide
5-135
Clocking in Serial Environment
When the MCU is connected directly to both ISDN lines and serial lines, the
MCU synchronizes its clock with the ISDN network clock.
In a serial only environment, the DCE, which is connected to a T1/E1 line,
synchronizes its clock with the ISDN network clock. This clock is transferred
via the serial connection to the MCU, but only when the serial connection is
active (i.e. when it transfers a call to/from the MCU). Therefore, when
starting a conference, the participant whose span is set as the primary clock
must be connected first and disconnected last when terminating the
conference as this participant provides the clocking signal for the system.
In a serial only environment, you must define one span as
Primary
clock and
another span as
Backup
clock.
1.
Connect to the MCU.
2.
In the
Browser
pane click the plus [+]icon next to the
MCU
icon, to list
its options.
3.
Double-click the
MCU Configuration
icon, or click on the plus [+] icon
next to the
MCU Configuration
icon, to list the
Configuration
options.
4.
Double-click the
Cards
icon or click the plus [+]icon next to the
Cards
icon to list the MCU slots.
5.
Double-click the slot containing the module you want to configure, or
click the plus [+] icon next to the card icon.
The MPI units are displayed in the
Browser
pane and in the
Status
pane.
6.
Right-click the unit you want to configure, and then click the desired
option.
Select
Set As Primary Clock Source
or
Set As Backup Clock Source
according to the desired configuration.
Содержание MGC Administrator
Страница 1: ...MGC Administrator s Guide Version 7 5 ...
Страница 4: ......
Страница 50: ...Chapter 2 Software Installation 2 32 ...
Страница 408: ...Chapter 6 Defining Operators 6 12 ...
Страница 482: ...Chapter 7 Configuring the Gateway 7 74 ...
Страница 496: ...Chapter 8 Audio and Video Conversion Tools 8 14 ...
Страница 534: ...Appendix B PPP Setup B 24 ...