Chapter 5 - MCU System Management
5-138
2.
Fill in the dialog box as follows:
3.
Click
OK
.
Table 5-17: Communications Properties
Parameter
Description
Message Timeout
If no message is received from the MCU for the time
period specified in this field, an error is triggered. The
default value is 25 seconds. A higher value should be
entered when the connection is slow or all the slots in
the MCU are occupied. In these cases, the
recommended value is 120 seconds.
Refresh Period
The frequency at which the MCU information in the
MGC Manager screen is updated. The refresh rate is
half of the seconds entered here. The default value is
2, which means that the information is refreshed
every second (2/2=1).
Max Replies Miss
The number of messages that are sent and not
received before a connection problem is triggered
and the system considers the connection as lost.
Connection Retries
The number of times the MGC Manager attempts to
establish a connection with an MCU following a
disconnection, or connection loss. Minimum value
should be 1.
Connection
Timeout
The number of seconds the MGC Manager will wait
after each connection attempt for connection
confirmation. Default value is 5. Recommended value
is 25.