MGC Administrator’s Guide
5-115
Video+ Logger
The Video+ Logger is a utility that records diagnostic information about the
Video+ cards. This information is used by Polycom personnel to identify
problems on the card.
When an error occurs on the Video+ card, a trace file may be created
automatically (if the appropriate option is selected in the system.cfg), or
manually via IP terminal. The Video+ trace file is automatically stored on the
MCU and can be retrieved using the
Retrieve Diagnostic Files
utility. The file
can then be analyzed to determine the problem.
Video+ Logger File Structure
The files are stored under the folder:
7.256\mcu\vp_log
The Video+ card diagnostic file header contains the following fields:
•
Date and Time
•
MCMS Version Number
•
Board ID, component ID
•
Video+ component versions
—
MNG_FILE (card manager)
—
VIDEO_PLUS_PROCESSOR_FILE (map)
—
VIDEO_PLUS_FPGA_FILE (bcod)
The log data is comprised of Card Manager data and/or map log from a faulty
unit. Each logger file can be up to 72KB, including header.
Creating the Video+ Logger Files
The Video+ logger file may be created automatically or manually.
Automatic creation of the Video+ logger files
The automatic creation of the Video+ trace-capture file is controlled by a flag
in the “system.cfg” in the
CARDS
section:
AUTO_VIDEO_PLUS_LOGGER.
This flag may be set to one of the following options:
•
NO
(Logger mechanism is activated only as a response to IP Terminal
command)
•
YES
(Logger mechanism is activated automatically, once a failure
occurs)
Содержание MGC Administrator
Страница 1: ...MGC Administrator s Guide Version 7 5 ...
Страница 4: ......
Страница 50: ...Chapter 2 Software Installation 2 32 ...
Страница 408: ...Chapter 6 Defining Operators 6 12 ...
Страница 482: ...Chapter 7 Configuring the Gateway 7 74 ...
Страница 496: ...Chapter 8 Audio and Video Conversion Tools 8 14 ...
Страница 534: ...Appendix B PPP Setup B 24 ...