MGC Administrator’s Guide
5-61
System.cfg Flags
Section TRACE OUTPUT
•
PRINT = IP
Defines the port to be used for Serial Traces.
The flag may be set to one of the following values:
—
Console - Trace to the Console.
—
Serial_1 - on the back (Also of the MGC-25).
—
Serial_2 - front (Not applicable for the MGC-25).
—
IP
•
TRACE = EXCEPTION
Default Tracing level.
This flag may be set to one of the following values:
—
NO- no trace
—
INTERACTIVE - level –I (accept input from terminal without
dumping to trace)
—
EXCEPTION- level –e Asserts, memory exceptions
—
INTO_MCMS_TRACE - level –g (embedded to mcms information)
—
T120 - level –t GCC Trace
—
FULL - full information
Section LOGGER TRACE
•
TRACE_LOGGER_APPLICATION = YES
Use this flag to enable (YES) or disable (NO) the Logger Utility.
•
TRACE_LOGGER_LEVEL = INTO_MCMS
Indicates the detail level of messages to be saved to the Logger file.
(INTO_MCMS, EXCEPTION, FULL)
Only those flags which are intended for customer modification are documented
here.