Appendix A: Faults
A-12
NO
_
AUDIO
_
MESSAGE
_
IN
_
CONFIGURATION
major
Occurs when the MESSAGE flag in the
system.cfg file, ATTENDED section is
configured to
YES
, but there is no
suitable hardware in the system.
NO
_
CLOCK
_
SOURCE
major
This error usually
follows a red, blue or
yellow alarm. If the MCU fails to
identify the PRI line it is unable to
synchronize itself by the PBX.
NO
_
MUSIC
_
IN
_
CONFIGURATION
major
Occurs when the MUSIC flag in the
system.cfg file, ATTENDED section is
configured to
YES
, but there is no
suitable hardware in the system.
PASSWORDS
_
CONFLICT
__
PLEASE
_
SEE
_
pscnflct_log_
FILE
_
FOR
_
DETAILS
startup
The password assigned to a
conference or reservation loaded from
a previous version is not valid in the
current version. For details see the
pscnflct.log file in the MCU root
directory.
POWER
_
SUPPLY
_
FAILURE
Applicable to MGC-25 only.
The power supply failed.
RESET
_
MCU
_
BY
_
OPERATOR
minor
The MCU was reset by the MGC
Manager from the
Reset MCU
sub-
menu.
SINGLE
_
CLOCK
_
SOURCE
minor
Only one span was able to synchronize
itself with the PBX. The system will
continue to function normally but there
will be no backup clock source. If there
are more than one net (T1 or E1) cards
connected to the PBX, this may
indicate a problem with the connection
to the PBX.
Table A-6: General Fault Descriptions (Continued)
Code
Level
Description
Содержание MGC Administrator
Страница 1: ...MGC Administrator s Guide Version 7 5 ...
Страница 4: ......
Страница 50: ...Chapter 2 Software Installation 2 32 ...
Страница 408: ...Chapter 6 Defining Operators 6 12 ...
Страница 482: ...Chapter 7 Configuring the Gateway 7 74 ...
Страница 496: ...Chapter 8 Audio and Video Conversion Tools 8 14 ...
Страница 534: ...Appendix B PPP Setup B 24 ...