48
2-3-3 Rotation of Standard Head Scanner
For the standard head models (LP-RH300S / LP-RH200S / LP-RH100S / LP-RH301S / LP-RH101S / LP-RH305S), the
angle of the head scanner unit can be set freely.
This function is specific to the standard head model. It is not equipped in the tower head model.
Rotation Method
• The head scanner can be rotated up to 350 degrees by loosening the hexagon socket head cap screw (M4). After
rotating the scanner unit, fix it tightly.
• The tightening torque shall be 1.5N·m.
Loosen
Approx. 200 degree
Approx. 150 degree
M4 Hexagon Wrench
WARNING
• Never use the laser marker with the setscrew for scanner angle loosened.
Failure to do so could rotate the head during the operation and cause laser
emission to the dangerous direction.
Center of Rotation
Unit: mm
51.2
130
158.4
91
8.3
14.2
41
115.5
8.3
28
29.2
129.2
31.8
29.2
129.2
31.8
107.2
63
3.5
141
161
61
3.5
11
9
End Standard
for Base
Approx. 60°
Center of
Rotation Axis
Approx. 20°
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......