2-1 Installation Environment
Use this product in the following environments.
Item
Installation environment conditions
Operating ambient temperature *1
0°C to +40°C
Operating ambient humidity *1
35 to 85%RH
Ambient temperature for storage *1
-10°C to +60°C *2
Pollution degree
2
Use location
Indoor; at an altitude of 1000 m or below
*1 : No condensation or freezing shall be allowed.
*2 : If there is a gap between the stored temperature and operating temperature, make sure to have the product get used
to the operating ambient temperature gradually prior to use to prevent the dew condensation.
ワㄐㄕㄊㄆ
• Do not install this product at a place where vibrations and shocks can be directly transmitted to it.
• Do not use this product at a place with oil mist.
• In case this product is used in a dusty environment, take measures to prevent dust from entering into the controller, e.g.
using a storage housing.
• When installing the controller in the storage housing, use a housing equipped with panel cooler or heat exchanger to
maintain the air-cooling performance of the laser marker according to the ambient temperature.
Panel cooler or
heat exchanger
Storage housing image
• Remove any dust and smoke from the laser emission port and laser beam path using a dust collector. For effective dust
collection, put the suction port of the dust collector near the lasing position. In an environment where dust and smoke
that tend to attach to the lens surface, it is recommended to create a compression air flow to ensure thorough dust collection.
ABC
ABCD
AB
Compressed
air
Dust collector
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......