216
Troubles
Causes
Measures
The sending
command is not
accepted and
negative response is
returned.
Alarm or Warning occurred.
All commands except the following commands * cannot be
accepted while alarm or error is active.
When alarm occurred:
• Status checking (STS)
• I/O monitor (IOM)
• Operating data (RTD)
• Error history (ERH)
• Alarm reset (ARS)
• Error code (ENO)
• Command mode (RSM)
When warning occurred:
• Status checking (STS)
• I/O monitor (IOM)
• Operating data (RTD)
• Error history (ERH)
• Alarm reset (ARS)
• Error code (ENO)
• Shutter open/close (SHT) (Only closing and readout request)
• Command reception permission (MKM) (readout only)
• Command mode (RSM)
Two or more command data
are transmitted at the same
time.
After sending the command, confirm the response data from the
laser marker. Do not send the next command before receiving
the response.
Command mode (setting
for the compatible mode) is
wrong.
• If you want to use the same command format with the former
models of LP-400/LP-V series, or LP-M/LP-S/LP-Z series, set
“Compatible mode” in system settings of Laser Marker NAVI
smart.
• If you want to use the standard command format, switch the
mode by RSM command or set “OFF” to “Compatible mode”
in system settings of Laser Marker NAVI smart.
• For LP-GS/LP-RC/LP-RH/LP-RF/LP-RV series, you cannot
use the LP-M/S/Z compatible mode.
The character code is wrong.
• Check the setting for “Encoding for non-ASCII characters” in
the “System settings”.
• Check if characters in the readout strings can be encoded with
ASCII code or the character code specified in “Encoding for
non-ASCII characters”.
• “Shift JIS”, “GB 2312” and “Latin-1” cannot be used together.
• In LP-400/V or LP-M/S/Z compatible mode, only ASCII code
and Shift JIS are available.
* These commands are applicable with the standard command mode. For the LP-400/V or LP-M/S/Z compatible mode,
refer to the “Serial Communication Command Guide: LP-400/V compatible mode”, or “Serial Communication Command
Guide: LP-M/S/Z compatible mode”.
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......