202
Troubleshooting
If any operation errors occur, check items below.
When the problems cannot be resolved, please contact our sales office or representatives.
Start-up
Troubles
Causes
Measures
• Power supply is not
turned on.
• The system does not
start up.
Power cable is not connected.
Connect the power supply cable.
Key switch is not turned on.
Turn on the key switch.
Power is not supplied.
Check the power supply.
The internal circuit is faulty.
Check if there is any problem with the external
power supply with the laser marker removed.
If there is no problem with the external power
supply, the internal circuit is assumed to be faulty.
Please consult your Panasonic representative.
Contact our sales office.
For LP-GS series:
Fuse is blown.
Replace the fuse by following the procedures
described in the “Setup/Maintenance Guide”.
For LP-RC//LP-RH/LP-RF/LP-RV/LP-
ZV series:
Circuit protector is OFF.
Turn on the circuit protector by following the
procedures described in the “Setup/Maintenance
Guide”.
Laser pumping
Troubles
Causes
Measures
Laser pumping
does not start.
The connection of the following I/O terminals is
released.
• INTERLOCK 1(+) - INTERLOCK 1(-) (X16 - X17)
• INTERLOCK 2(+) - INTERLOCK 2(-) (X18 - X19)
• For LP-GS series:
LASER STOP 2 IN (X11) - OUT COM. 1
• For LP-RC/LP-RH/LP-RF/LP-RV/LP-ZV series:
REMOTE INTERLOCK IN (X20) - OUT COM. 1
• Check the connection of each terminal
on the I/O terminal block.
• If the safety equipment such as door
and switch is in released status, restore
the original condition.
The stop laser button of the configuration software is
pressed.
• Solve the safety problem. Then select
“Reset” in the error dialog in Laser
Marker NAVI smart to finish the laser
stop status.
• For LP-RH/LP-ZV if you use the
optional touch panel console or monitor,
select “Reset” on its screen.
Power is not supplied to the common terminal of the
I/O terminal block.
Connect the internal or external power
supply to IN COM.1 and OUT COM.1 in the
I/O terminal respectively.
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......