To transfer a part of the code string read, set the data
extraction.
If “OFF” is selected, the read string is transmitted as is.
To set the data extraction, specify the start position and
data length of the code data in bytes.
Setting range:
• Extraction start position: 1 to 299 byte
• Extraction length
• Character transmission: 1 to 299 byte
• File switching by name: 1 to 299 byte
• File switching by number: 4 byte (fixed)
Extraction example: To read code characters “ABCDE” and transfer “BCD” to the laser marker, set as follows:
• Extraction start position [byte]: 2
• Extraction length [byte]: 3
ンㄆㄇㄆㄓㄆㄏㄆ
• Count one single byte character as one byte.
• The data extraction position setting applies to all data read by this function.
• If the read data length is shorter than the string to extract, the code is not read.
• Set the checksum setting of the code reader RS-232C communication settings to “OFF”. If the checksum is set to “ON”,
the communication checksum is transferred to the laser marker as marking data.
• The end code (CR) is not subject to the data extraction.
7.
If the control contents are set to character data
transmission, specify the object number of destination.
The read character data are transmitted to the object
number specified here.
Check the file to use this function and specify an
appropriate object number.
Object numbers available as object numbers of
destination are as follows.
• Object numbers for which character object is set
• Object numbers for which a bar code or 2D code
object is set
ンㄆㄇㄆㄓㄆㄏㄆ
• If there is not object number set as an object number of
destination other than a character in the file to use this
function or code is set for the number, character data
cannot be transmitted.
8.
Select “Apply to laser marking system” on the left side of the ribbon.
9.
Disconnect the online connection with the laser marker.
10.
Turn off the power of the laser marking system, wait five seconds and then restart the system.
The configured items will be reflected to the laser marker.
“Apply to laser marking
system” tool
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......