221
ERROR
CODE
Description
Measures *1
E040 - E043
E140 - E143
E221 - E222
E240 - E243
• Incorrect connection of signal cable or unit
power cable.
• An error has occurred to the internal system of
the laser marker.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
For LP-GS/RC/RH/RF series, check the
connection between laser head and controller.
For LP-RV/ZV series, check the connection
between laser head and oscillator unit and
between oscillator unit and controller.
• Replace the cable.
E059 *4, *6
E159 *4, *6
E231 - E236
Network unit error.
Check if the optional network unit is installed to
the controller correctly.
E200 - E201
INTERLOCK safety relay is out of order.
Contact our sales office or representatives.
E205 - E207
• Abnormality occurs on the internal shutter.
• Signal cable is not connected properly.
Check the connection of the cable and various
signal lines, and then restart the laser marker.
E216 - E217
An error occurred in the controller fan.
• Clean the air intake and exhaust port and fan
located at the air cooling area of the controller.
• If the air filter is contaminated, replace it.
• Replace the fan.
E220
Laser head housing is open.
Contact our sales office or representatives.
E225 *4
Fiber unit is detached.
Install the fiber unit properly by following the
procedures described in the “Setup/Maintenance
Guide”.
E226-E229 *6
An error occurred in the head fan.
• Clean the air intake and exhaust port located
at the air cooling area of the head.
• If the air filter is contaminated, replace it.
• If it happens again, contact our service center or
sales offices.
E237 *5, *6
An expansion board error occurred.
Check if the optional expansion board is installed to
the controller correctly.
E250 - E255
E260 - E261
E264 - E265
• An error has occurred to the laser oscillator.
• A power supply voltage error was detected in
the laser oscillator.
• Incorrect connection of signal cable or unit
power cable.
• Check and correct the power status.
• Check if the AC power line is affected by noise.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
• For LP-RC series:
Check if the ambient temperature of the
laser marker is not exceeding the range of its
specification.
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......