136
4-6-19 Interlock input
If INTERLOCK (X16 - X17 and X18 - X19) is opened, the laser pumping is turned off and the shutter is closed, regardless of
whether or not the laser is radiating. Refer to “Laser marker operation when functions for safety measures are input” (P.100).
T3
T1
T1
T1
T1
T1
T1
T2
T2
T2
T3
T3
T5
T5
T5
T7
T4
T4
T4
T6
T8
T8
T8
ON (Close)
OFF (Open)
ON (Normal)
OFF (Error)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
CLOSE
OPEN
CLOSE
OPEN
CLOSE
OPEN
CLOSE
OPEN
ON
OFF
TRIGGER IN (X5)
INTERLOCK 1 (X16-X17)
INTERLOCK 2 (X18-X19)
INTERLOCK 1 MONITOR
(Y16-Y17)
ALARM RESET IN (X15)
SHUTTER CLOSE 1 OUT (Y8)
SHUTTER CLOSE 2 OUT (Y9)
READY OUT (Y5)
PROCESSING OUT (Y10)
PROCESSING FAIL OUT (Y12)
ALARM OUT (Y15)
INTERLOCK 2 MONITOR
(Y18-Y19)
SHUTTER ENABLE IN (X9)
SHUTTER IN (X8)
LASER SUPPLY IN (X6)
LASER STANDBY OUT (Y6)
Item
Time
Remarks
T1
Approx. 50ms
INTERLOCK MONITOR is switched open and closed with a delay of approx. 50ms with
reference to each INTERLOCK input.
T2
Max. 1 sec.
There is a delay time of around 200ms to max. 1 second from turning ON/OFF of
SHUTTER IN (X8) to turning ON/OFF of SHUTTER CLOSE 1 OUT (Y8) and SHUTTER
CLOSE 2 OUT (Y9).
T3
100ms or more
Keep the ON status for 100ms or more.
T4
Approx. 5 to 10 sec.
Time for completion of laser pumping.
• At the usual operation: Approx. 5 sec.
• Re-pumping right after turning the laser pumping OFF: Max. 10 sec.
T5
―
The time until when the shutter is opened or the total of marking data creation time,
whichever is longer.
T6
2ms or more
Keep the ON status for 2ms or more.
T7
2 to 510ms
This is One-shot output. Set the output time on the environment setting screen. There is
a small margin of error for the setting value.
T8
Max. 1 sec.
After the laser pumping is completed, there is a delay time of max. 1 second until when
SHUTTER CLOSE 1 OUT (Y8) and SHUTTER CLOSE 2 OUT (Y9) are turned OFF.
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...