118
Item
Time
Remarks
T1
Approx. 10 sec.
Time for system startup. Turn ON the remote mode upon verifying SYSTEM STANDBY
OUT (Y7).
T2
Approx. 5 sec.
Time for completion of laser pumping.
• At the usual operation: Approx. 5 sec.
• Re-pumping right after turning the laser pumping OFF: Max. 10 sec.
T3
Max. 1 sec.
There is a delay time of around 200ms to max. 1 second from turning ON/OFF of
SHUTTER IN (X8) to turning ON/OFF of SHUTTER CLOSE 1 OUT (Y8) and SHUTTER
CLOSE 2 OUT (Y9).
T4
―
Setup time of the laser marker to start the marking trigger processing.
• In the laser pumping completed state: Total time for shutter opening (T3) and marking
data creation. It varies depending on the quantity of the setting data.
• When the laser pumping is not completed: Total time for shutter opening (T3) and
marking data creation, or time for laser pumping, whichever is longer.
T5
2ms or more
Keep the ON status for 2ms or more.
T6
―
When TRIGGER IN (X5) is accepted, PROCESSING OUT (Y10) turns ON. The output time
of PROCESSING OUT (Y10) includes the trigger delay time, marking preparation time,
laser radiation time, and processing time after marking has completed.
T7
2 to 510ms
One-shot output. Set the output time on the environment setting screen.
There is a small margin of error for the setting value.
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......