128
4-6-10 Guide laser radiation input
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON (Close)
OFF (Open)
T3
T2
T1
T4
SHUTTER ENABLE IN (X9)
SHUTTER IN (X8)
SHUTTER CLOSE 1 OUT (Y8)
SHUTTER CLOSE 2 OUT (Y9)
SELECT 0 - 2 IN (No.19-21)
GUIDE IN (No.23)
*1
*2
READY OUT (Y5)
Item
Time
Remarks
T1
Max. 1 sec.
There is a delay time of around 200ms to max. 1 second from turning ON/OFF of
SHUTTER IN (X8) to turning ON/OFF of SHUTTER CLOSE 1 OUT (Y8) and SHUTTER
CLOSE 2 OUT (Y9).
T2
0ms or more
Turn on GUIDE IN (No.23) with the shutter closed.
T3
0.5ms or more
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN, turn on
GUIDE IN.
T4
Max. 60 sec.
The guide laser is stopped automatically after passing 1 minute from start-up.
*1 : Select the indication contents of the guide laser with SELECT 0 IN to SELECT 2 IN as follows.
Radiation details
SELECT 0 IN (No. 19)
SELECT 1 IN (No. 20)
SELECT 2 IN (No. 21)
Work distance
OFF
OFF
OFF
Marking image
ON
OFF
OFF
Marking field
OFF
ON
OFF
Masked objects
ON
ON
OFF
*2 : Keep the input state of SELECT 0 IN to SELECT 2 IN (No.19-21) while GUIDE IN (No.23) is turned ON.
ンㄆㄇㄆㄓㄆㄏㄆ
• To use a guide laser in remote mode while any of the INTERLOCK inputs (REMOTE INTERLOCK IN, INTERLOCK
1, INTERLOCK 2) is open, set “Deactivate while shutter closed” in “System settings” > “Operation/information” >
“INTERLOCK alarm detection”.
• If you have configured the guide laser control method of external control to communication commands by the system
settings of Laser Marker NAVI smart, the guide laser radiation by I/O is not possible.
• Do not execute any other operation while the guide laser is emitted.
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......