194
5.
Loosen the bolts (M4, two positions) of the contactor with hexagonal screwdriver and remove the contactor unit from
the controller.
6.
Install the new contactor unit. Insert the bolt to the washer and
tighten the bolts (two positions) with M4 hexagonal screwdriver
to fix the contactor unit to the controller.
Tightening torque: 1.0 N·m
ワㄐㄕㄊㄆ
• Be careful not to let the cable get caught while installing.
ンㄆㄇㄆㄓㄆㄏㄆ
• To the optional contactor unit, the cables are already connected at
the delivery state.
7.
Connect the two connectors of the contactor to the
controller.
8.
Connect the cable of the contactor to the controller cable
ties (2 positions).
9.
Install the side panel on the controller and tighten the
following screws.
Five M3 screws on the back
One M3 screw on the top
Two M3 screws on the side
Tightening torque: 0.5 N·m
ワㄐㄕㄊㄆ
• Be careful not to let the inside cables get caught while
installing.
Washer
Bolt
Connector
Cable tie
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......