Bar code marking data (Shift-JIS code specified) : BRS
Sets character string to be encoded as a bar code or 2D code by shift-JIS code. For characters including control code
(specified with 2-bytes alternate codes), KANA, KANJI and function characters.
•
Setting / Readout data of bar code marking data
STX
BRS
Sub
command
[Bar code No.] [Line No.]
[Bar code data]
Max. 63-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
•
Readout request of bar code marking data
STX
BRS
R
[Bar code No.] [Line No.]
Max. 3-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Bar code No.
1
“0”–“7”
Line No.
1 or 2
1D code: “1”–“2”
2D code: “1”–“9”
2D part of Composite code: “01”–“09”
Specifies the line for data setting.
Bar code data
Max. 60
Specifies the character string within 30 characters with shift-JIS code for setting
in the specified line.
However, for the functional characters, specifies in ASCII code characters with
beginning with “%” (25(HEX)).
Reference
•
When setting bar code marking data in multiple lines, data in each line are jointed in the order of line numbers and they
are coded as the data in one line. (No line break is inserted for each line.)
•
When setting bar code marking data in multiple lines, make sure the sum of all barcode data is 255 characters or less.
•
If readout data includes function characters (such as “%SFT:0”), the setting character (“%SFT:0”) is read out, but
characters to be actually marked are not.
• For the method to specify bar code data, refer to “Setting method of character string for marking (specified with shift-JIS
code)” (P.86). and “Functional character (specified with ASCII code)” (P.86).
•
To input the control codes in the barcode/2D code strings, set the code data as follows:
•
To include the control codes in the strings, set the all control codes with BRS command by using these 2-byte
alternate codes instead of ASCII code. In this case, set the other characters including alphanumeric by using shift-
JIS code.
Control code
00 (HEX)
to
1F (HEX)
7F (HEX)
Alternate code
F050 (HEX)
to
F06F (HEX)
F071 (HEX)
•
The following control codes EOT, FS, GS, RS, or US you can set with BBS command by using ASCII code. Refer to
“Bar code marking data (ASCII code specified) : BBS” (P.95).
•
To input “FNC1” for CODE128, GS1 Data Matrix, GS1 DataBar Expanded, and 2D side of Composite code, use the
following alternate code. In this case, set the other characters including alphanumeric by using shift-JIS code.
Control code
FNC1
Alternate code
F072 (HEX)
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...