93
⿎
Lot character string : LTS
Sets the character string used for “Lot Function” to change characters depending on date/time and counter values.
•
Setting / Readout data of lot character string
STX
LTS
Sub
command
[Lot No.] [Period unit] [Start period]
[End period] [Marking character string]
Max. 33-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
•
Readout request of lot character string
STX
LTS
R
[Lot No.] [Period unit]
3-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Lot No.
1
“0”–“7”
“4”–“7”: common lot
Period unit
2
Period condition
Setting range
Year, week-
based year
“01”–“60”
Month
“01”–“12”
Day
“01”–“31”
Y/M
“01”–“60”
M/D
“01”–“60”
Hour
“01”–“24”
Minute
“01”–“60”
Hour/Minute
“01”–“60”
Week
“01”–“54”
Day of Week
“01”–“07”
Counter
“01”–“60”
The setting range varies depending
on the condition of period unit.
Start period
6
Period condition
Setting range
Year, week-
based year
“198000”–“209900”
Month
“000001”–“000012”
Day
“000001”–“000031”
Y/M
“198001”–“209912”
M/D
“000101”–“001231”
(The higher 4 characters:
month, the lower 2
characters: date)
Hour
“000000”–“000023”
Minute
“000000”–“000059”
Hour/Minute
“000000”–“002359”
Week
“000000”–“000054”
Day of Week
“000000”–“000006”
(“000000”: Sunday,
“000006”: Saturday)
Counter
“000000”–“999999”
The start / end period of marking the
character string for setting is set.
The setting range varies depending on
the condition of period unit.
Set “??????” for both of start and end
period to delete it.
“??????” is indicated if the period
which has not been set is read out.
End period
6
Marking
character
string
Max. 18
Use the shift-JIS code.
(Up to 9 characters)
The character string to be marked with
the specified period is set. Specify
0-byte of data length to delete the
character string of period.
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...