ERROR
CODE
Error details
Measures
E320
Unit combination is incorrect.
•
Connect head control cable properly, and restart
with key switch.
•
Check if head with correct model has been
connected. If it is wrong, replace head or controller
with correct one.
E410
to
E443
E990
to
E999
System error.
Restart the laser marker.
When not recovered,contact to our sales office.
E450
to
E456
Memory error.
E700
Unable to lase as laser pumping is turned OFF.
• Confirm that the laser pumping remains on during
lasing operation.
•
Check wiring and control procedure for the I/O
terminal block, wiring to communication port, and
the procedure of the communication command.
Reference
•
When other error not listed in this section was occurred, restart the laser marker.