124
Name
Data
length
[byte]
Description
Remarks
Character
height
7
Model type*
Setting range [mm]
LP-V10
“000.100”–“090.000”
LP-4x0
“000.100”–“110.000”
LP-4x5/LP-V15 “000.100”–“160.000”
LP-4x1/LP-W
“000.100”–“055.000”
Character width
7
Center position
X
8
“-300.000”–“+300.000” [mm]
The center coordinate for arc is indicated.
Center position
Y
8
Radius
8
“+000.000”–“+300.000” [mm]
Radius of line
interval
7
Model type*
Setting range [mm]
LP-V10
“000.000”–“090.000”
LP-4x0
“000.000”–“110.000”
LP-4x5/LP-V15 “000.000”–“160.000”
LP-4x1/LP-W
“000.000”–“055.000”
The difference of radius from the center position
of marking position to the next line is indicated
when the character string is marked over two or
more lines.
Start angle
7
“-180.00”–“+180.00” [°]
The angle from the positive (+) side of X
coordinate with counter-clockwise at the first
character in character string for marking is
indicated.
Angle of
character
interval
7
“-180.00”–“+180.00” [°]
The angle between the center of character and
the center of next character is indicated.
Font No.
1
“1”: character font 1
“2”: character font 2
The number corresponding to the 2 fonts
previously registered is indicated.
Bold line width
5
Model type*
Setting range [mm]
LP-V10/LP-W
“0.000”–“2.000”
LP-4x1/LP-V15
“0.000”–“4.000”
LP-4x0/LP-4x5
“0.000”–“6.000”
Laser power
correction
3
“000”–“200” [%]
•
The correction ratio is calculated using the
value set at the laser setting as 100%.
•
With LP-400/LP-W series, nothing should be
input in Laser Pulse Cycle Correction.
Scan speed
correction
3
“005”–“500” [%]
(Laser
pulse cycle
correction)
(Only for LP-V
series)
(3)
“050”–“200” [%]
* For the detail of the model type, refer to “Target laser marker” (P.8).
Reference
•
At marking of bold characters, set the values so ratio of character height to character width be within 1/4 to 4.
•
Set the Bold Line Width to 1/4 or less of the character height or the character width, whichever is smaller.
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...