Connecting to external control devices
•
To connect an external device and the laser marker directly one to one:
Use a Category 5e or higher cross cable for connection.
Reference
•
If the external control device has the AutoMDI/MDI-X function, either a straight cable or a crossed cable can be
connected to the laser marker.
External control device
(PC, etc.)
Cross cable
Laser marker controller
•
To connect an external device and the laser marker one to many through a HUB or a router:
Use a HUB (or a router) that supports 1000BASE-T/100BASE-TX/10BASE-T and Category 5e or higher straight cables
for connection.
HUB (or router)
Straight cable
External control device
(PC, etc.)
Laser marker controllers
(connected more than one unit)
Example of communication environment setting:
Make sure that the IP address for the laser marker on the network is not overlapping the IP address for the PC.
PC
Laser marker A
Laser marker B
Laser marker C
Laser marker D
IP address
192.168.1.10
192.168.1.5
192.168.1.6
192.168.1.7
192.168.1.8
Subnet mask
255.255.255.0
Default gateway
None
Port
-
9094
9094
9094
9094
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...