47
2-4-2 Marking trigger input
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T1
T1
T2
READY OUT
MARKING OUT
TRIG. IN
WARNING OUT
(Active low)
Item
Time
Remarks
T1
10ms or more
Keep the ON status for 10ms or more.
T2
2 to 510ms
It outputs a warning to notify that an invalid trigger was input when a marking trigger was
input during the marking operation. This is One-shot output. You can turn this warning off
by the settings.
Reference
•
The marking is started when TRIG. IN is turned to ON while either the delay time or delay distance is 0.
2-4-3 Equidistant marking (Flying object marking)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T2
T2
T2
T3
T3
T3
T3
T1
READY OUT
TRIG. IN
MARKING OUT
MARK END OUT
Item
Time
Remarks
T1
―
The time when the work travels the distance set in the “trigger delay”.
T2
―
The time when the work travels the distance set in the “interval” of the moving object.
T3
2 to 510ms
One-shot output. Set the output time on the environment setting screen. There is a small
margin of error for the setting value.
Reference
•
Equidistant marking is performed while TRIG. IN is ON.
•
The laser marker stops after marking is completed if TRIG. IN is turned to OFF during marking.
•
Equidistant marking is performed after travels the distance that is set in the “trigger ready”.
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...