48
2-4-4
Select file
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T1
T2
T4
T5
T6
T4
T3
T2
T1
READY OUT
MARKING OUT
SET OK OUT
TRIG.IN
SET IN
D0 to D15 IN
SELECT 0 to 2 IN
Item
Time
Remarks
T1
0.5ms or more
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN
to D15 IN, turn on SET IN.
T2
0ms or more
Keep the input until the SET OK is turned to ON.
T3
2 to 510ms
One-shot output. Set the output time on the environment setting screen. There is a
margin for the setting value.
T4
―
•
When laser pumping is completed
Period for creating marking data. It varies depending on the quantity of data to be
marked.
•
When laser pumping is not completed
Period for creating marking data or period until the laser pumping is completed. The
longer one of the two above is employed.
T5
0ms or more
To input the next file number right after TRIGGER IN, input SET IN after MARKING OUT
turns ON.
T6
10ms or more
Keep the ON status for 10ms or more.
Input SELECT 0 to 2 as the table below.
Number input target
SELECT 0 (No. 20)
SELECT 1 (No. 21)
SELECT 2 (No. 22)
File No.
OFF
OFF
OFF
Reference
• If marking is still being performed at the time SET input is turned to ON, the file will be changed after marking is
completed.
•
TRIG.IN is acceptable while the READY is turned to ON.
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...