59
⿎
RS-232C communication conditions
Item
RS-232C communication conditions
Synchro system
Start-stop method
Communication
Full-duplex transmission
Baud rate
1200 / 2400 / 4800 / 9600 / 19200 / 38400 bps (initial setting: 9600 bps)
Data length
8-bit fixed
Parity
None / Even / Odd (initial setting: None)
Stop bits
1-bit / 2-bit (initial setting: 1-bit)
Flow control
None
Check sum
OFF / ON (initial setting: OFF)
Delimiter
CR / CR + LF (initial setting: CR)
Start code
•
Setting request, Reading request, Reading response: STX
•
Normal response: ACK
•
Abnormal response: NAK
Reception timer
Timeout monitoring ON (10 sec.)
Reference
•
For the details of the setting method of communication conditions, refer to “1-3-2 Communication condition setting” (P.21).