Arbitrary point radiation coordinate and time : PRD
Sets arbitrary point radiation X/Y coordinates, radiation time and laser power correction ratio.
•
Setting of arbitrary point radiation coordinate and time
STX
PRD
S
[Point radiation condition No.] [Start line] [Radiation time]
[Laser power correction] [X position] [Y position] [• • •]
[X position] [Y position]
15+16n-byte
(Check
sum)
Delimiter
•
Setting of radiation time, and laser power correction only
STX
PRD
S
[Point radiation condition No.] [Line No.] [Radiation time]
[Laser power correction]
15-byte
(Check
sum)
Delimiter
•
Delete of arbitrary point radiation condition
STX
PRD
S
[Point radiation condition No.] [Start line] [End line]
8-byte
(Check
sum)
Delimiter
•
Readout request of arbitrary point radiation coordinate and time
STX
PRD
R
[Point radiation condition No.] [Line No.]
5-byte
(Check
sum)
Delimiter
•
Readout data
STX
PRD
A
[Point radiation condition No.] [Line No.] [Radiation time]
[Laser power correction] [X position] [Y position]
Max. 31-byte
(Check
sum)
Delimiter
When there is no setting data in the selected line, [Radiation Time], [Laser Power Correction], [X Coordinate] and [Y
Coordinate] fields are not existed.
Name
Data length
[byte]
Description
Remarks
Point radiation
condition No.
2
“00”–“15”
Line No.
3
“000”–“049”
Start line
3
“000”–“049”
End line
3
Radiation time
7
“00000.1”–“99999.9” [ms]
Laser power
correction
3
“000”–“200” [%]
The correction ratio is calculated
using the value set at the laser setting
as 100%.
X position
8
Model type*
Setting range [mm]
LP-V10
“-045.000”–“+045.000”
LP-4x0
“-055.000”–“+055.000”
LP-4x5/LP-V15
“-080.000”–“+080.000”
LP-4x1/LP-W
“-027.500”–“+027.500”
Y position
8
* For the detail of the model type, refer to “Target laser marker” (P.8).
Reference
•
The coordinate numbers that can be set or read out at once are max. 50 points.
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...