34
⿎
Operation of input signal on I/O connector
Reference
•
The ON/OFF listed in this section refers to the ON/OFF operations. It does not refer to the voltage level (High/Low).
Terminal
No.
Name/Description
1
•
For NPN models *1
IN COM.: Input common
The common terminal for each input of the I/O terminal and I/O connector. This No. 1 and A2 of I/O
terminal are the common terminals connected internally.
For NPN models, this terminal is connected to the “+ (plus)” side of power which is used for control.
•
For PNP models (“-C” in the end of the model name) *1
OUT COM.: Output common
The common terminal for each output of the I/O terminal and I/O connector. This No. 1 and A2 of I/O
terminal are the common terminals connected internally.
For PNP models, this terminal is connected to the “+ (plus)” side of power which is used for control.
Notice
•
Do not invert the power wiring of I/O terminal and I/O connector. It may cause a failure. When IN COM. and OUT COM.
in the I/O terminal are connected to the power supply, it is not necessary to supply the power to IN COM. or OUT COM.
in I/O connector.
2
SET IN
Turn on this signal when executing the input of D0 to D15 and SELECT 0 to SELECT 2.
Turn on SET IN with maintaining the input status of D0 to D15 and SELECT 0 to SELECT 2. The input
operation is executed at the timing of the edge of turning on.
SET IN is required to control the following operations by I/O.
•
File No. selection
•
Correct the count-up/count-down value of the counter function
•
Reset the count value of the counter function
•
Switch marking characters of the rank function
•
Switch marking coordinates of the external offset function
3 to 18
D0 to D15 : Number input
Set the number for one of the following targets selected at SELECT 0 to SELECT 2.
For the detail of SELECT 0 to SELECT 2, refer to the description of terminal No. 20 to 22.
1) File No.
2) Count-up value correction
3) Count-down value correction
4) Counter No. to reset
5) Data number for Rank /External offset function
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...