1-3-1 DIP switch setting
Set the operational options for the external control with the DIP switch equipped on the controller rear side.
Reference
•
The initial setting of all DIP switches is OFF.
•
Turn OFF the power at DIP switch setting.
•
For the details on DIP switch, refer to Operation/Maintenance manual.
1.
Turn OFF the power of laser marker.
2.
Remove the DIP switch cover on the rear of the controller.
ON
OFF
Rear of controller
LP-400 series
LP-V/LP-W series
DIP switch
3.
With DIP switch No. 2, select the control method, I/O or command
for some specific operations.
DIP switch No. 2
Control method for specific operations
ON
Control by serial communication commands for the
following operations
•
Laser pumping (LSR)
•
Shutter control (SHT)
•
Guide laser (GID)
•
Laser check radiation (SPT)
•
Power check (PWR) (LP-V/LP-W series only)
OFF (initial setting)
Control by I/O for the following operations
•
Laser pumping
•
Shutter control
Reference
•
“Guide Laser Control”, “Laser Check Radiation” and “Power Check” cannot be controlled by I/O. They can be controlled
only by using serial communication in the remote mode.
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...