80
⿎
Status request: STS
Requires the operation status of laser marker, such as ready status and error occurrence status.
•
Status request
STX
STS
R
(Check sum)
Delimiter
•
Response to status request
Read out with the following format:
STX
STS
A
[Error occurrence status] [Laser pumping status]
[Command reception status] [Marking ready status]
[Trigger status]
5-byte
(Check sum)
Delimiter
Name
Data
length
[byte]
Description
Remarks
Error occurrence
status
1
“0”: no error
“1”: error occurrence
Laser pumping
status
1
“0”: laser pumping OFF
“1”: laser pumping
“2”: laser pumping completed
Command
reception status
1
“0”: Shutter close or command
reception mode ON
(including while the shutter is
opened)
“1”: Shutter open
(excepting when the command
reception mode is ON)
Shutter and command reception mode (MKM
command) status is indicated.
Use this for determination of whether various
commands can be transmitted. For details,
refer to “Command Reception Condition”.
Marking ready
status
1
“0”: marking disable (ready OFF)
“1”: marking enable (ready ON)
The status of marking trigger acceptability is
indicated.
Trigger status
1
“0”: trigger OFF
“1”: Trigger ON
The status of trigger input (TRIG.IN) is
indicated when “equidistant marking” is
selected at trigger condition.
Reference
•
Marking is enable when the response data is either “02110” or “02111”.
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...