manualshive.com logo in svg
background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Содержание 199

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...the Model 199 SystemoMM as well as the optional Model 1992 Scan ner Also included are programming examples for various IEEE 488 co mllers 01998 Keith Instruments Inc Cleveland Ohio U S A Document Num...

Страница 3: ...ADING TIMES DEVICE DEPENDENT COMF SCANNER PROGRAMMING DATA FORMAT STATUS WORD FORMATS SRO MASK AND STATUS E TRANSLATOR CONTROLLER PROGRAMS _ JIANDS COMMANDS _ IYTE FORMAT ___ _ _ Y _ i _ j 1 2 5 6 7 9...

Страница 4: ...not touch any terminals while the instrument is turned on or connected to any other test equipment 4 Do not exceed the maximum input levels es stated in the specifications for the instrument bee the...

Страница 5: ...er programmed parameters SELECT ON User programmed interval mnsec to 999 999sec DMM SETUP SHIFTDMM SETUP to enter menu NEXT to scroll to next menu option REV Displays current software revision level r...

Страница 6: ...panel LEDs and annunciator A I L LEDS OFFS r DEBUG YES Enter troubleshooting mode A V L DEBUG NO L RESET YES Returns Ynit to factory default configuration Lo RESET NO SCAN SETUP SHIFT SCAN SETUP to e...

Страница 7: ...fminimum time abet ween channels r ON Channels 2 through 8 referenced to channel 1 RATIO A V I OFF l Ratio operates only on a fixed ange Range changes will restart et channel 1 In MANUAL et least one...

Страница 8: ...No data in data store when recalling Pressing SCANNER or SCAN SETUP with no scanner Attempting calibration with calibra tion locked CHAN 4 MAX Channel 4 limit Cpole CHAN 8 MAX Channel 8 limit IZ pole1...

Страница 9: ...mmed intervals INTER VAL OVERRUN message indicates programmed inter val is too short for present instrument configuration with data store or scanner only One Shot 1 Press SHIFT TRIG SETUP then uprange...

Страница 10: ...ress any function button to turn off data store One shot Data Storage 1 Program the one shot trigger mode using TRIG SETUP 2 Press SHJFT STORE to enter data store S Pmgram the number of readings size1...

Страница 11: ...display the reading 3 Use uprange or downrange to scroll through readings The scroll rate becomes more rapid after holding button in 4 Press RECALL to display reading number then press NEXT to return...

Страница 12: ...ree with power line frequency for optimum noise performance SAVE YES NO Select operating modes then SAVE YES to store present instwment configuration Unit will assume the saved configuration upon powe...

Страница 13: ...SCAN SETUP and program 2 4 pole mode 2 Press NEXT then use uprange downrange to select STEP mode 3 Press NEXT and select ratio on or off as desired 4 Press NEXT to return to normal operation S For in...

Страница 14: ...ing use TRIG SETUP to select one shot trigger mode and delay 7 Press SCANNER then program the desired channel limit haximum limit 4 for 4 p mode S lf interval scanning was selected the unit will begin...

Страница 15: ...e Scanning 1 Press SHIFT TRIG SETUP and select ONE SHOT trig ger mode 2 Press NEXT and program desired trigger delay Omsec 999 999sec 3 Press NEXT to return to normal display 4 press SHIFT SCAN SETUP...

Страница 16: ...e INTERVAL setting In SCAN mode sum of l 41 x number channels scanned is the minimum interval setting l When using the scanner with STEP or SCAN switching the DMM will take readings on each channel as...

Страница 17: ...verter set tling time typically lsecl See Model 199 specifications l The scanner operates with the set of instrument parameters programmed prior to start of scanning Chang ing any of these parameters...

Страница 18: ...c L133msecl MUX OFF 63msec l7Smsecl Times in parenthesis are for 50Hz operation1 vpical Autoranging Times DCV DCA ACV ACA OHMS l3OOkQ range and lower1 350msec 1 4sec 500msec Times shown are to correct...

Страница 19: ...DCA ACA RO Auto AM0 AM0 AlltO Rl 3OOilW 300mV 30mA 30mA R2 3 3v 3A 3A R3 3ov 3ov 3A 3A R4 3oov 3oov 3A 3A R5 3oov 3oov 3A 3A R6 3oov 3oov 3A 3A R7 3ODV 3oov 3A 3A 16 Artisan Technology Group Quality...

Страница 20: ...20 21 22 PO P P2 Internal and front panel filter disabled Internal filter enabled Front panel filter enabled Rate I so Sl 4 digit resolution 2 59msec integration period 5 digit resolution line cycle i...

Страница 21: ...ger Individual readings from data Data store size IO In Wrap around data store mode Data S NB of n In 1 to 5001 Default interval 175msec ISELECT OFF I n interval in milliseconds 15msec to 999999msec I...

Страница 22: ...e LlI Save present machine states as default conditions G4 G7 without prefix Reading and channel with orefix ding and channel without I prefix Reading buffer location and channel with prefix Reading b...

Страница 23: ...isable EOI enable bus hold off on x Enable EOI disable bus hold off on x Disable both EOI and bus hold off on x status uo 1 U2 u3 4 5 Send machine status word Send error conditions Send Translator wor...

Страница 24: ...y period in milliseconds lornsec to 999999msec Self test JO Test ROM RAM EzPROM Hit Button H Hit front panel button number n Display up to 10 character message a charac er Cancel displav mode 21 Artis...

Страница 25: ...4 MAX ERROR ERROR STEP NlO Stop scan all channels open 2 W Limit 4 Pole Limit N11 1 1 N12 2 2 N13 3 3 N14 4 N15 5 CHAN 4 AX ERROR N16 6 CHAN 4 MAX ERROR N17 CHAN 4 MAX ERROR Nl6 CHAN 4 MAX ERROR N19...

Страница 26: ...ERROR Scan Interval 00 Default 175msec interval ISELECT OFF1 Qn n in erval in m ec 15r999999mser l Trigger Delay Wn n delay in msec l0 999999msec Delay to be used as channel settling time 23 Artisan T...

Страница 27: ...DATA FORMAT Figure 1 Data Format Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 28: ...STATUS WORD FORMATS Figure 2 uo status word Format Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 29: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 30: ...U2 U5 Status Words 27 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 31: ...SRQ MASK AND STATUS BYTE FORMAT Figure 4 SRQ and Status Byte Format 28 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 32: ...s Translator words Terminates definition string Wildcard definition character Enables Ranslator Disables Translator Saves Translator words as power up default Returns list of Translator words Purges T...

Страница 33: ...ar memory left llse of more than one ALIAS in definition Translator word exceeds 31 characters Use of X in a Translator word Defined word already exits character used in definition character sent by i...

Страница 34: ...e user and are not intended to suit specific needs Each program allows you to rend a device dependent command string to the instrument and obtain and display an instru ment reading string 31 Artisan T...

Страница 35: ...e IEEE 486 interface installed in the IBM computer 3 Type in BASICA on the computer keyboard to get into the IBM interpretive 8ASIC language 4 Place the interface software disk in the default drive ty...

Страница 36: ...string to 199 Dimension reading input string Get reading string from 199 Display reading string on CRT 2 In order for Translator to function properly a CR LF seq ence must be added to the end of any...

Страница 37: ...e Model 199 to 26 2 With the power off connect the Model 199 to the IEEE 466 interface installed in the IBM computer 3 Tum on the computer then boot up BASICA 4 Type in the program lines shown below u...

Страница 38: ...odify the program as follows 188 R RL IDb R r5 12 185PRlHTR 2 For use with a card memory address other than C400 modify the DEFYSEG statement in line 10 accordingly For example with a card memory addr...

Страница 39: ...he power off connect the Model 199 to the HPIB interface installed in the computer 3 Enter the computer EDIT mode 4 Enter the lines in the program below using the ENTER key after each line 6 Run the p...

Страница 40: ...Address 199 to listen send string Address 199 to talk input reading Display reading string Repeat NOTE For ccnversion fo a numeric variable change the pro gram as follows 37 Artisan Technology Group Q...

Страница 41: ...o 26 2 With the power off connect the Model 199 to the IEEE 498 interface installed in the Apple ll computer 3 Enter the lines in the program below using the RETURN key after each line 4 Run the prcgm...

Страница 42: ...199 to talk input data Untalk the 199 Define output to CRT Define input from keyboard Display reading string Repeat 1 If converSion to numeric variable is required make the following changes 2 The Ap...

Страница 43: ...nnect the Model 199 to the HP82937A GPIB interface installed in the HP 85 computer 3 Enter the lines in the program below using the END LlNE key after each line 4 Press the HP 85 RUN key and type in t...

Страница 44: ...ut command string Address 199 to listen send string Address 199 tc talk input reading Display reading string Repeat NOTE For conversion to numeric variable change line 70 as follows 41 Artisan Technol...

Страница 45: ...the Model 199 to the 98034A HPlB interface installed in the 9825A 3 Enter the lines in the p mgram below using the STORE key after each line Line numbers are automaticaliy assign ed by the 9825A 4 Pre...

Страница 46: ...e Prompt for command string Address 199 to listen Address 159 to talk input data Print data string on printer Repeat NOTE For conversion to numeric variable modify the pro gram as follows 43 Artisan T...

Страница 47: ...erface cable 3 Enter the program below using the editor under RT 11 and the name IEEE FOR 4 Compile using the FORTRAN compiler as follows FOR TRAN IEEE 6 Link with the system and IB libraries as follo...

Страница 48: ...Set line feed as terminator Tim on remote input primary address Prompt for command string Program instrument Address 199 to listen send string Get data from instrument Untalk the 199 Raw 45 Artisan Te...

Страница 49: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: