10 Controlling with the operational unit
-
91
-
10.3 Monitor mode
In monitor mode, the current position of the motor will be displayed in real time.
TEACH
AX1
AX2
MON
EDIT
Displays the current position LED for axis 1
LED for axis 2
Switches between axes 1 and 2
Displays the sign
When the power of the operational unit is turned on, the unit automatically displays the current position
of axis 1 and illuminates the AX1 LED. If the movement-amount unit has been set with the UNIT
command, the display will be in movement units. If the value is negative, the space to the left will
display a minus sign.
In monitor mode, every time
or
is pressed, the current positions for axis 1 and axis 2 are
displayed in turn, illuminating their respective LEDs.
If you press
or
, the number of the sequence program under execution and the line number will
be displayed. To return to the current position display, press
or
.
TEACH
AX1
AX2
MON
EDIT
Sequence program number
Line number
Содержание EMP400 Series